Skip to main content

Cockpit-Simulator

SPAD.neXt supports these devices of Cockpit-Simulator (also sold as Cockpitmaster):

DevicePage
737 MCP, MCP-LITE737 MCP
737 EFIS left and right737 EFIS
A320 FCU, A320 EFIS left and rightA320 FCU & EFIS
CDU (v1) and v2 CDU: 320A MCDU, 737X, 737M, 747X, 777X CDUCDU
737X TQ-1, 737X TQ-2, 737M TQ, FireProtect 737737 TQ & FireProtect
danger

All Cockpit-Simulator devices are complete edition features.

Turning on the support​

  1. Open the SPAD.neXt settings and turn on Enable Cockpit-Simulator Support.
  2. Each device type has its own switch (CDU, Boeing EFIS, Boeing MCP, Airbus FCU, Airbus EFIS, Boeing TQ, Boeing Fire Protection). All are on by default; turn a type off if SPAD.neXt should leave those devices alone, for example because another program uses them.
  3. Restart SPAD.neXt.

Each device gets its own page in SPAD.neXt, named CS and the device, for example CS MCP or CS TQ.

Chained devices​

Several Cockpit-Simulator devices can be connected to each other with chain cables, so that only one of them is connected to the PC with USB. SPAD.neXt finds all devices of the chain through that one USB connection.

  • The MCP or the FCU must be the device connected with USB, the EFIS panels are chained behind it.
  • The FireProtect panel is chained behind the TQ; the TQ is connected with USB.
  • The 24 V power connection is required for chaining.

The CDUs are always connected on their own with USB.

Power and brightness​

All Cockpit-Simulator devices follow the SPAD.neXt virtual power: with power on they use the power-on brightness, with power off the power-off brightness (dark by default) and the lights are off.

In the settings, every device type has a brightness for power on and one for power off (0 = dark, 255 = full). The power-on brightness can also be changed by your programming at any time with the device's brightness variables, for example to follow the panel light knob of the aircraft. The variables are listed on the page of each device.

Reconnect and disconnect​

Each device page has the buttons Reconnect and Disconnect. Use Reconnect if a device stopped reacting, for example after it was switched off and on again. SPAD.neXt also reconnects by itself when the USB connection is lost and comes back.

Names in the programming​

Buttons, switches, encoders, displays and lights keep the same names in every profile, for example I_APP for the APP button of the MCP. Device variables start with LOCAL:CS_ and the device, for example LOCAL:CS_MCP_BACKLIGHT. Devices that exist twice (left and right EFIS) have _L or _R in their variable names.